Assessment OICEW-7-1A
Start emergency generator
Assessed in EN-4131 Internal Combustion Engines II
Condition
Aboard ship or in an approved simulator, given access to generator and proper tools.
Performance Requirements
| Behavior | Standard | 
|---|---|
| The student will: | During assessment, the student shall, at a minimum: | 
|  
 Check that system is ready to start  | 
 Meet requirements of OICEW 7-1B  | 
| 
 Start the generator  | 
 Turn generator mode selector switch to manual Turn generator starting switch to start  | 
| 
 Check that generator starts properly  | 
 Check: 
  | 
Supports Table A-III/1 officers in charge of an engineering watch
| Competence | Knowledge, Understanding & Proficiency | Task | 
|---|---|---|
| 
 Operate electrical, electronic and control systems  | 
 B1.1 Basic configuration and operation principles of the following electrical equipment: 
  | 
 Start emergency generator  | 
Published: 2016-10-28-04:00