Assessment OICEW-7-1A
Start emergency generator
Assessed in EN-4131 Internal Combustion Engines II
Condition
Aboard ship or in an approved simulator, given access to generator and proper tools.
Performance Requirements
Behavior | Standard |
---|---|
The student will: | During assessment, the student shall, at a minimum: |
Check that system is ready to start |
Meet requirements of OICEW 7-1B |
Start the generator |
Turn generator mode selector switch to manual Turn generator starting switch to start |
Check that generator starts properly |
Check:
|
Supports Table A-III/1 officers in charge of an engineering watch
Competence | Knowledge, Understanding & Proficiency | Task |
---|---|---|
Operate electrical, electronic and control systems |
B1.1 Basic configuration and operation principles of the following electrical equipment:
|
Start emergency generator |
Published: 2016-10-28-04:00