Assessment OICEW-4-3E
Monitor main gas turbine operation
Assessed in EN-3233 Steam and Gas Turbines
Condition
On a gas-turbine vessel of at least 1,000 HP at sea, on a simulator, or in a laboratory.
Performance Requirements
| Behavior | Standard | 
|---|---|
| The student will: | During assessment, the student shall, at a minimum: | 
| 
 Shift controls  | 
 shift/change over controls from local or main control room to bridge control  | 
| 
 Adjust engine speed as required  | 
 adjust throttles to match engine order telegraph (EOT)  | 
| 
 Monitor main gas turbine engine  | 
  | 
| 
 Monitor gas turbine alarms  | 
 respond to alarms and take corrective actions as necessary  | 
Supports Table
| Competence | Knowledge, Understanding & Proficiency | Task | 
|---|---|---|
| 
 Operate main and auxiliary machinery and associated control systems  | 
 A4.3 Preparation, operation, fault detection and necessary measures to prevent damage for the following machinery items and control systems: 
  | 
 Monitor main gas turbine operation  | 
Published: 2016-10-28-04:00