NVIC Method
Show NVIC method.
|  STCW Competence  | 
 Knowledge, Understanding, and Proficiency  | 
| 
           Operate main and auxiliary machinery and associated control systems 
         | 
            OICEW-A4.3  Preparation, operation, fault detection and necessary measures to prevent damage for the following machinery items and control systems 
          Steam boiler and associated auxiliaries and steam systems 
         | 
|   Condition  |  Behavior  | Standard  | 
| 
           On a vessel of at least 1,000 HP, on a simulator, or in a laboratory, under the supervision of the Chief Engineer, and when directed, 
         | 
           the candidate performs a bottom blow of a boiler. 
          
  
          
         | 
           The candidate: 
          
            - 
              
Performs bottom blow when directed, slowing main engine to prevent carry-over or other adverse affects on steaming boiler; 
             
            - 
              
Secures fires in boiler and opens superheater vent to boiler; 
             
            - 
              
Secures main-steam stops to boiler to be given bottom blow; 
             
            - 
              
Using auxiliary feed stop-check, raises level of water in steam drum of boiler to 1 inch from the top of gauge glass; 
             
            - 
              
Opens bottom blow overboard skin valve; 
             
            - 
              
Opens water wall bottom blow valve; 
             
            - 
              
Observes drop in water level, securing bottom blow valve when level is no less than 1 inch from bottom of gauge glass; 
             
            - 
              
Repeats steps 4 and 5; 
             
            - 
              
Opens mud drum bottom blow valve and secures when gauge glass water level drops to no less than 1 inch from the bottom; 
             
            - 
              
Prepares to re-light boiler; 
             
            - 
              
Starts boiler forced draft fan and pre-purges furnace for 5 minutes; 
             
            - 
              
Raises water level to 2 inches below normal level; 
             
            - 
              
Re-lights burner  and adjusts combustion air as necessary; 
             
            - 
              
Opens main steam stops to “float” boiler back on line, cracks open superheater and main steam line drains; 
             
            - 
              
Begins to return main engine to sea speed when boiler pressures are observed to be equal and slight drop in burner manifold fuel oil pressure is noted; 
             
            - 
              
Closes off superheater and main steam drains, and superheater vent; 
             
            - 
              
Continues to slowly re-establish engine speed; and 
             
            - 
              
Conducts round of engine room to verify that all steam systems and equipment are operating at normal levels. 
             
           
         | 
 
MMA Method
In order to satisfy   NVIC 17-14 Task 4.3.L  , MMA students must:
  - Successfully complete MMA Assessment OICEW-5-2C Bottom blow boiler