Condition
Using an approved simulator, in the laboratory, or aboard ship and given access to an air compressor.
Performance requirement
Behavior | Standard |
---|---|
The student will: | During assessment, the student shall, at a minimum: |
Check unit for readiness to start |
Inspect mechanical condition of equipment Observe sufficient lubricating oil Blow down receiver and moisture traps On water cooled units, verify coolant flow |
Line-up compressor |
Verify compressor discharge valve is open |
Start compressor |
press start button verify control set to automatic |
Monitor operation of air compressor |
Verify operation of unloader Verify operation of cut-in and cut-out switches |
Secure the air compressor |
Press the stop button Leave compressor lined up to start |
Location
Assessed in EN‑2111 Auxiliary Machinery II.
References
- Table A-III/1 OICEW-A4.1
- NVIC 17-14 Task 4.1.A
Lab Manual
Auxiliary Machinery II Laboratory Manual
See the Assessment Guidelines for additional specifications of behavior and standards.