| On a steam vessel, on a simulator, or in a laboratory, | the candidate assists in manual light- off, raising steam, and cutting-in on line a main- propulsion boiler. 
 | The candidate: 
Checks all burner fuel oil root valves closed;Opens the forced draft damper, all air register doors, start the forced draft fan in high speed, and purge the furnace for a few minutes;Lines up the fuel-oil system to recirculate through heater (if fitted) and brings oil up to temperature as specified and notifies the watch engineer;Makes up a burner atomizer with a small sprayer plate and inserts it into a central register designated for light-off (#1), closes air register doors, and opens steam and fuel oil root valves for #1 burner;Adjusts forced draft damper for low fire and adjust the fuel-oil pressure to the minimum pressure specified for successful combustion;Opens the steam atomizing valve of burner #1 and allows steam to flow to at least one minute to clear header of condensate;Closes the fuel oil recirculation valve, open burner #1 air register doors, and readjusts fuel pressure to minimum required;Lights the torch or activate lighter ignition (go to step 15);Inserts the torch through the manual light-off opening;Stands clear of open register doors;Holds the torch near and just under the atomizer tip;Cracks open the burner valve;Checks for ignition; opens the burner valve wide when ignition occurs and fire stays lit (closes burner valve and purges furnace if ignition does not occur or if fire goes out);Withdraws the torch (if used);Inspects the fire through the peep hole;Checks the periscope for smoke and adjust the ratio of fuel to air needed for a steady flame and to avoid smoking while achieving complete combustion;Closes superheater drains when blowing clear of condensate;Throttles steam drum atmospheric vent when steam pressure starts to rise;Closes steam drum atmospheric vent at pressure specified by watch engineer;Throttles in on superheater vent valves, ensuring that they are not closed until the boiler is on line;Monitors steam drum water level and maintain the water level with the auxiliary feed stop check as necessary;As line pressure is approached, inserts additional atomizers into the idle burners and cut in atomizing steam;When steam drum pressure exceeds line pressure, opens the auxiliary, then the main steam stop valves, bringing the boiler on line;Closes the superheater vent valves;Switches the automatic combustion control system and feedwater regulating system to automatic as appropriate;Notifies the watch engineer of any unusual or unsafe conditions; andTakes proper action to prevent safety and pollution violations. |