RFPEW Task 1.1.B(M)
Monitor electricity generating plant (Motor)
MMA Method
In order to satisfy NVIC 07-14 Task 1.1.B(M) , MMA students must:
- Successfully complete MMA Assessment OICEW-4-1D Monitor engineering machinery
NVIC Method
See NVIC method.
STCW Competence |
Knowledge, Understanding, and Proficiency |
Carry out a watch routine appropriate to the duties of a rating forming part of an engine-room watch.
|
RFPEW-A1.2 Engine-room watchkeeping procedures
|
Condition | Behavior | Standard |
On a motor vessel, on a simulator, or in a laboratory,
|
the candidate monitors the electrical generating plant.
Note 5
Not performing this task will limit the candidate’s endorsement to gas-turbine propelled and/or steam vessels.
|
The candidate:
- Checks plant’s operational status;
- Checks diesel generator rpm;
- Checks diesel generator frequency;
- Checks diesel generator output voltage;
- Checks diesel generator output amperage;
- Checks diesel generator kilowatt output;
- Checks diesel generator kilovolt-amp reactive output or power factor, as appropriate;
- Checks diesel generator bearings’ temperature and oil flow;
- Checks governor, turbocharger, and diesel engine sump lube-oil levels;
- Checks the physical condition of pipes, tubing, and hoses for wear or leaks;
- Observes diesel engine lube-oil and cooling-water temperatures and pressures;
- Observes diesel engine air intake and exhaust temperatures and pressures, including air-intake filter pressure drop, as appropriate;
- Checks start air pressure
- Reads fuel-oil meter, day-tank levels, and observes operation of viscosimeter, if installed;
- Checks for any unusual conditions or noises;
- Notifies the watch engineer of any unusual or unsafe conditions; and
- Takes proper action to prevent safety and pollution violations.
|