RFPEW Task 1.1.B(M)

Monitor electricity generating plant (Motor)

MMA Method

In order to satisfy NVIC 07-14 Task 1.1.B(M) , MMA students must:

NVIC Method

See NVIC method.

STCW Competence Knowledge, Understanding, and Proficiency

Carry out a watch routine appropriate to the duties of a rating forming part of an engine-room watch.

RFPEW-A1.2 Engine-room watchkeeping procedures

Condition Behavior Standard

On a motor vessel, on a simulator, or in a laboratory,

the candidate monitors the electrical generating plant.


Note 5 Not performing this task will limit the candidate’s endorsement to gas-turbine propelled and/or steam vessels.

The candidate:

  1. Checks plant’s operational status;
  2. Checks diesel generator rpm;
  3. Checks diesel generator frequency;
  4. Checks diesel generator output voltage;
  5. Checks diesel generator output amperage;
  6. Checks diesel generator kilowatt output;
  7. Checks diesel generator kilovolt-amp reactive output or power factor, as appropriate;
  8. Checks diesel generator bearings’ temperature and oil flow;
  9. Checks governor, turbocharger, and diesel engine sump lube-oil levels;
  10. Checks the physical condition of pipes, tubing, and hoses for wear or leaks;
  11. Observes diesel engine lube-oil and cooling-water temperatures and pressures;
  12. Observes diesel engine air intake and exhaust temperatures and pressures, including air-intake filter pressure drop, as appropriate;
  13. Checks start air pressure
  14. Reads fuel-oil meter, day-tank levels, and observes operation of viscosimeter, if installed;
  15. Checks for any unusual conditions or noises;
  16. Notifies the watch engineer of any unusual or unsafe conditions; and
  17. Takes proper action to prevent safety and pollution violations.