AFF Task 3.2.A
Inspects ship’s firefighting equipment for compliance with applicable rules and regulations
MMA Method
In order to satisfy NVIC 09-14 Task 3.2.A , MMA students must:
- Pass MMA Course FF-0106 2/C Firefighting Practicum
NVIC Method
See NVIC method.
STCW Competence |
Knowledge, Understanding, and Proficiency |
Inspect and service fire detection and fire- extinguishing systems and equipment
|
AFF-X3.2 Requirements for statutory and classification surveys
|
Condition | Behavior | Standard |
In an approved or accepted course, in simulated shipboard conditions,
|
the candidate pre- inspects the ship’s firefighting equipment for compliance with the applicable rules and regulations.
|
The candidate will conduct a pre-inspection of the ship’s firefighting equipment, including:
The currency of the inspection certificates and records for portable fire extinguishers;
Determining which portable fire extinguishers require recharging and/or hydrostatic testing;
The currency of inspection certificates and records for semi-portable fire extinguishers;
Determining which semi-portable fire extinguishers require recharging and/or hydrostatic testing;
The currency of the inspection certificates and records for fixed fire extinguishers;
Determining which fixed fire extinguishers require recharging and/or hydrostatic testing;
Determining continued suitability of various pieces of equipment for their specified service including:
a. fire nozzles;
b. deluge system piping and nozzles;
c. fireman’s outfits;
d. spanners;
e. valves;
f. axes; and
g. hoses; and
The validity of other documentation that may be required by the inspector.
|