OICEW-5-2B
Secure main boiler
Condition
In an approved simulator or aboard a ship in port or at anchor, given access to a main boiler.
Performance requirement
Behavior | Standard |
---|---|
The student will: | During assessment, the student shall, at a minimum: |
Secure boiler |
Reduce load on boiler Place combustion control on manual Secure fires Open superheater vents and drains |
Secure forced draft fan | |
Monitor boiler until stable |
Maintain water level in drum Open drum vent before pressure falls to 0 psi |
See the Engineering Assessment Guidelines for additional specifications of behavior and standards.