OICEW-5-1I
Shut down fuel oil or lube oil purifier
Condition
Using an approved simulator, in the laboratory, or aboard ship, given access to a running fuel oil or lube oil purifier.
Performance requirement
Behavior | Standard |
---|---|
The student will: | During assessment, the student shall, at a minimum: |
Secure the purifier oil heater | |
Secure purifier |
Close purifier suction valve Stop purifier motor Use bowl brake to bring bowl to stop |
Secure piping system |
Close discharge valve Close other valves as required |
See the Engineering Assessment Guidelines for additional specifications of behavior and standards.
Note: This assessment supports KUP OICEW-A4.1, and is assessed in EN-3233 Steam and Gas Turbines.