OICNW-3-3C
Operational Settings - Display/change CPA/TCPA limits
Condition
On an operational ECDIS that meet the standards of IMO resolution MCS.232(82) 5 Dec 2006 revised performance standards for Electronic Chart Display and Information Systems (ECDIS) or an ECDIS simulator that meets applicable national and international performance standards for ECDIS.
Performance requirement
Behavior | Standard |
---|---|
The student will: | During assessment, the student shall, at a minimum: |
Display CPA/TCPA limits on the ECDIS unit. Change the CPA/TCPA limits based on navigational situation. |
Display CPA/TCPA target controls and change CPA/TCPA to a limit specified by instructor within 45 seconds. |
Note: This assessment supports KUP OICNW-A4.2, and is assessed in MT-3224 Electronic Chart Display & Information System (ECDIS).