OICEW-A4.3 Preparation, operation, fault detection and necessary measures to prevent damage for the following machinery items and control systems
Auxiliary prime movers and associated systems
|
Condition | Behavior | Standard |
On a motor vessel of at least 1,000 HP, on a simulator, or in a laboratory,
|
the candidate plans for and starts up the freshwater generator, describing actions as they are being performed.
|
The candidate:
-
Opens the brine pump/eductor overboard skin valve;
-
Opens the brine pump eductor saltwater supply valve;
-
Opens the vacuum pump/eductor saltwater supply valve;
-
Opens the saltwater feed pump discharge and suction valves;
-
Starts the saltwater feed pump to supply both the evaporator eductors;
-
Closes the vacuum breaker valve atop the evaporator shell;
-
Adjusts the brine overboard discharge valve to maintain water level to just cover submerged tube nest in bottom of distiller;
-
Delays continuing with operation until 75% of operational vacuum is attained;
-
Opens the main heat source valve to distiller heating section;
-
Adjusts the main-engine jacket water distiller heating section outlet valve to maintain proper jacket-water temperature differential between inlet and outlet;
-
Adjusts the saltwater feed to distiller to maintain proper inlet temperature;
-
Continues to regulate the brine overboard pump discharge to maintain seal and brine level;
-
Starts the distillate pump;
-
Energizes the salinity indicating panel and verifies the three- way valve is de-energized and distillate is re-circulated to the evaporator;
-
Energizes the salinity indicating panel and verifies the three- way valve is de-energized and distillate is re-circulated to the evaporator;
-
Continues to adjust the saltwater supply valve, controlling saltwater feed temperature, and brine overboard flow rate;
-
Monitors the distillate pump salinity level output;
-
Verifies the tank to be replenished is lined up;
-
Energizes the three-way valve when the distillate salinity level is below alarm level;
-
Verifies the salinity meter reading by comparing to chemical test of a 50 ml sample;
-
Records the meter reading once discharge to tank has been established; and
-
Takes proper action to prevent safety and pollution violations.
|