OICNW-3-2A
Set up and maintain an ARPA display
Function: Navigation at the operational level
Competence | Knowledge, Understanding & Proficiency | Task |
---|---|---|
Use of radar and ARPA to maintain safety of navigation |
A3.4 Ability to operate and to interpret and analyze information obtained from ARPA, including:
|
Set up and maintain an ARPA display |
Assessed in: MT-3222 Automatic Radar Plotting Aids
Condition
On an operational ARPA that meet the standards of 33 CFR 164.38 (or an ARPA simulator that meets applicable national and international performance standards for ARPA).
Behavior
Set up and maintain the ARPA display.
Standard
Within three minutes, the candidate:
- Turned the power on;
- Initialized performance monitor;
- Noted error messages;
- Switched from standby to on;
- Selected the appropriate scale;
- Adjusted the gain control so that targets and sea return appeared;
- Adjusted the tune control (if the unit is not self tuning);
- Adjusted the brilliance control;
- Adjust the sea clutter and rain clutter controls to suppress the rain and sea clutter without losing targets.
- Display selected is north up stabilized, relative motion.
- Select proper gyro course and speed input.
- Select sea stabilized mode.