OICEW-5-3C
Respond to boiler low water alarm
Function: Marine engineering at the operational level
Competence | Knowledge, Understanding & Proficiency | Task |
---|---|---|
Operate main and auxiliary machinery and associated control systems |
A4.3 Preparation, operation, fault detection and necessary measures to prevent damage for the following machinery items and control systems:
|
Respond to boiler low water alarm |
Assessed in: EN-3233 Steam and Gas Turbines
Condition
In an approved simulator or aboard a ship in port or at anchor, given access to a main or auxiliary boiler.
Behavior
Plan for and respond to a boiler low water alarm, describing actions as they are being performed.
Standard
- Plan reflects proper sequence of actions, is complete, and conforms to the requirements of manufacturer’s instructions and ship’s procedures;
- Response to low water alarm is timely, effective and conducted according to plan;
- Actions taken are correctly and completely described;
- Required steps taken are verified by assessor utilizing sample checklist as a guide;
- No safety violations are observed.