OICEW-5-1F
Start fresh water generator
Function: Marine engineering at the operational level
Competence | Knowledge, Understanding & Proficiency | Task |
---|---|---|
Operate main and auxiliary machinery and associated control systems |
A4.1 Basic construction and operation principles of machinery systems, including:
|
Start fresh water generator |
Assessed in: EN-4231 Sea Term IV Engine
Condition
Using an approved simulator, in the laboratory, or aboard ship and given access to a fresh water generator.
Behavior
Plan the start up of the fresh water generator and start up the fresh water generator, describing actions as they are being performed.
Standard
- Plan reflects proper sequence of actions, is complete, and conforms to the requirements of manufacturer’s instructions and ship’s procedures;
- Start up of the fresh water generator is successful and conducted according to plan;
- Fresh water is generated and water salinity is under 4.24 ppm;
- Actions taken are correctly and completely described;
- Required steps taken are verified by assessor utilizing sample checklist as a guide;
- No safety violations are observed.